Skip to product information
1 of 4

Portable Contec Touch MS400 Multi-parameter Patient Simulator ECG Simulator

Portable Contec Touch MS400 Multi-parameter Patient Simulator ECG Simulator

Regular price $508.50 USD
Regular price Sale price $508.50 USD
Sale Sold out

Introduction
MS400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it can be tested in where the monitor is used.


Functions
Simulate 35 kinds of arrhythmia (including Atrial, Ventricular, Premature Beat and Conduction Defects) and pacemaker waveforms (including Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non Capture, Non Function).
Simulate four-channel IBP data.
Simulate respiration signal with adjustable respiration rate, impedance and baseline impedance, and three kinds of apnea data.
Simulate four kinds of temperature data.
Simulate square wave, triangle wave, pulse wave and sine wave with adjustable frequency.
Simulate standard ECG calibration, adult and pediatric ECG signal.
ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG database, other ECG database and user-defined waveform data stored in TF card can be displayed by the simulator and exported to the equipments to be tested.
Each waveform can be displayed by sliding the 3.5\' TFT touch screen, easy to operate.
Power supply: rechargeable lithium battery or linear adapter, which reduces interference.
Optional operation modes: keys and touch screen.


Performance
1)ECG
Conventional
All leads have the same voltage with the II-lead as the reference
Amplitude
0.5,1.0,1.5 and 2.0mV
ECG Rate
15,20,25,30,40,60,80,100,120,140,160,
180,200,220,240,260,280,300,320,340and 350 BPM
ECG artifacts
50 and 60 Hz, muscle, baseline and breathing
The elevation of the ST segment
+0.8 to -0.8 mV, the step is 0.1 mV
2)Arrhythmia
Atrial
Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus
Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm,
Supraventricular Tachycardia
Ventricular
Vent Fib (coarse), Vent Fib (fine), PVCs 6/min, PVCs 12/min,
PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy,
Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia,
Asystole
Premature Beat
Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R
on T LV Focus,PVC2 RV Focus, PVC2 E RV Focus, R on T RV
Focus, Multifocal PVC
Conduction Defects
First Degree Heart Block, Second Degree Heart Block, Third
Degree Heart Block, Right Bundle Branch Block, Left Bundle
Branch Block.
3)Four IBP Channels
The default
00/00mmHg
Dynamic IBP(unit: mmHg)
Channel 1
Artery 120/80
Radial 120/80
Left Ventricle 120/00
Right Ventricle 25/00
Channel 2
Artery 120/80
Radial 120/80
Left Ventricle 120/00
Right Atrium(CVP) 15/10
Right Ventricle 25/00
Pulmonary Artery 25/10
Pulmonary Wedge 10/2
Left Atrium 4/4
Channel 3
Artery 120/80
Radial 120/80
Left Ventricle 120/00
Right Atrium(CVP) 15/10
Right Ventricle 25/00
Pulmonary Artery 25/10
Pulmonary Wedge 10/2
Left Atrium 14/4
Channel 4:
Auto Swan-Ganz (every 15 seconds) RA(CVP), RV, PA, PAW (Pulmonary Wedge)
Man Swan-Ganz press ENTER key to change every time
Static-Pressure Levels
Channel 1
0, 80, 160, 240, 320 and 400mmHg
Channel 2
0, 50, 100, 150, 200 and 250mmHg
Channel 3
0, 20, 40, 60, 80 and 100mmHg
Channel 4
P4 tracks the static pressure levels of P3
4)Respiration
Respiration Rate
0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
Impedance
0.2, 0.5, 1.0 and 3.0 Ω
Baseline impedance
500, 1000, 1500, 2000Ω
Apnea
12 s, 22 s, 32 s
5)Temperature
Four temperature
0℃(32°F), 24℃( 75°F), 37℃(98.6°F), 40℃(104°F)


Accessories
Standard accessories
9V/1A(CE) power adapter, an User manual, a packaging box,
a plastic packaging.

View full details